(iv) Lasting volumetric enlargement might not exceed 10 percent of the total volumetric enlargement at exam tension.

(i) The porous materials may not disintegrate or sag when soaked with solvent or when subjected to usual provider;

The completed cylinders needs to be uniformly and adequately warmth dealt with prior to checks. Warmth remedy of cylinders in the authorized analyses must be as follows:

Markings may very well be stamped into the sidewalls of cylinders possessing a support strain of one hundred fifty psig if all of the next problems are fulfilled:

Tension-retaining products needs to be determined by any ideal process that doesn't compromise the integrity in the cylinder. Plates and billets for hotdrawn cylinders has to be marked with the heat quantity.

(3) Every test cylinder will have to face up to flattening to nine instances the wall thickness with out cracking. If the alternate bend examination is utilized, the test specimens must keep on being uncracked when bent inward all-around a mandrel from the course of curvature in the cylinder wall till the inside edges are in a distance aside not larger compared to the diameter from the mandrel.

Reheat therapy of rejected cylinders is licensed. Subsequent thereto, cylinders ought to move all prescribed checks to generally be suitable. Welds might be repaired by appropriate ways of fusion welding.

(iv) A brass fitting may be brazed into the metal boss or flange on cylinders used as part parts of handheld fire extinguishers.

(two) The scale of any centered opening inside of a head may well not exceed one particular half the surface diameter of your cylinder.

(one) Every single cylinder should be heated and held at the right temperature for at least just one hour per inch of thickness dependant on the maximum thickness of your cylinder after which quenched in an acceptable liquid medium getting a cooling level not in extra of eighty percent of drinking water.

The minimal wall thickness should be this kind of that the wall stress at the minimum amount specified exam force will likely not exceed eighty % from the minimum amount produce energy nor exceed 67 percent of your minimum greatest tensile strength as confirmed by Actual physical assessments in paragraph (i) of this section.

(2) The inspector must validate ultrasonic inspection of all substance by inspection or by acquiring the material producer's certification of ultrasonic inspection. Ultrasonic inspection have to be carried out or verified as owning been done in accordance with paragraph (b)(5) of the part.

(6) Other markings are licensed delivered These are designed in lower pressure spots aside from the side wall and they are not click here of a dimension and depth that should generate hazardous strain concentrations. These kinds of marks may not conflict with any DOT required markings.

Notwithstanding the variation delivered in this paragraph, Each and every container must usually conform to some DOT 2Q container in accordance with § 178.33a. The subsequent circumstances also use less than Variation 2—